Hydraulic One-Trip
> Thru Tubing TFH
|
<< Return
|
Thru Tubing TFH
|
DESCRIPTION:
The TT-TFH is designed to run and fully set either bridge plugs or cement retainers inside 2 3/8 or 2 7/8inch tubing on coiled tubing then squeeze in one trip.
Run the TT-TFH/SVCR tool string below the predetermined setting depth, pick-up to removeslack, drop a ½” diameter brass ball then, pressure the workstring to establish a 1,000-psi differential atthe tool to begin the setting process.
Continue pressuring the workstring to establish a 2,000-psi differential at the tool and hold for 5 minutes.This allows the cement retainer packing system to conform to the tubing ID.
Continue pressuring the workstring to establish a differential at the tool to shear the cement retainer or bridge plug disconnect.
|
Tubing Size |
Tool O.D. |
Setting Range |
|
Min |
Max |
|
(in) |
(in) |
(in) |
(in) |
|
2 3/8, 4.0 - 5.9# |
1.71 |
1.867 |
2.0414 |
|
2 7/8, 6.4 - 6.5# |
2.160 |
2.280 |
2.563 | |
|
|
|
| |